Skip to main content

Table 1 Controller parameter sets

From: A control system analysis of the dynamic response of N-methyl-D-aspartate glutamate receptors to alcoholism and alcohol withdrawal

Parameter

Set A

Set B

Set C

Set D

Set E

y max1 (rec/hr)

25

25

25

25

25

n 1

2

2

4

2

4

a x (rec)

50

50

50

25

25

a z (rec)

50

50

50

25

25

k a

0.5

0.5

0.5

0.5

0.5

y max2 (rec/hr)

25

12.5

25

25

25

n 2

2

2

4

2

4

a 2 (rec)

100

100

100

50

50

Figure(s)

1,2*

3A

3B

3C

3D, 4, 5

  1. Values of parameters used for various analyses and the figures associated with the corresponding analyses. Bolded numbers highlight differences from Parameter Set A. *: For each panel of Figure 2, the indicated parameter was altered from its nominal value in Parameter Set A.