From: Numerical study of entrainment of the human circadian system and recovery by light treatment
Sleep-Wake Switch | Circadian Pacemaker | ||||
---|---|---|---|---|---|
Parameters | Values | Units | Parameters | Values | Units |
Q max | 100.00 | s −1 | Ω | 7.2722×10−5 | s −1 |
Θ | 10.000 | mV | γ | 0.13000 | − |
σ | 3.000 | mV | q | 0.60000 | − |
ν vm | − 2.1000 | mVs | k | 0.51000 | − |
ν mv | − 1.8000 | mVs | δ | 0.9944 | − |
ν vc | − 0.3000 | mV | β | 0.0070000 | s −1 |
ν vh | 1.0000 | mV | α 0 | 0.100000 | s −1 |
ν oc | 1.0000 | mV | p | 0.5 | − |
ν mo | 0.30000 | mVs | I 0 | 9500 | lux |
ν ov | − 1.0000 | mVs | I 1 | 100 | lux |
τ v ,τ m | 10 | s | G | 2220.0 | s |
τ o | 120 | s | ρ | 0.032000 | − |
χ | 40.000 | h | ε | 0.40000 | − |
μ m | 17.000 | − | r | 10.000 | − |
η h | 2.3000 | s −2 | I d | 600 | lux |
A v | − 8.5000 | mV | I n | 150 | lux |
A m | 0.52000 | mV | T d | 11.000 | h |
A o | 1.0000 | mV |